Parameters
List of parameters
1-284
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
23:
Save in a non-volatile fashion as setting 23 (reserved)
24:
Save in a non-volatile fashion as setting 24 (reserved)
25:
Save in a non-volatile fashion as setting 25 (reserved)
26:
Save in a non-volatile fashion as setting 26 (reserved)
1011: Save in volatile fashion, loaded with p0976=1011
1012: Save in volatile fashion, loaded with p0976=1012
1013: Save in volatile fashion, loaded with p0976=1013
Dependency:
Refer to: p0976, p1960, p3845, r3996
Caution:
The Control Unit power supply may only be powered-down after data has been saved (i.e. after data save has been
started, wait until the parameter again has the value 0).
It is not permissible that the CompactFlash card is withdrawn while saving data.
Notice:
Writing to parameters is inhibited while saving.
The progress while saving is displayed in r3996.
Note:
Parameters saved with p0977 = 10, 11 or 12 can be downloaded again with p0976 = 10, 11 or 12.
Description:
This parameter is an image of p0101 in conformance with PROFIdrive.
Parameters p0101 and p0978 contain the following information:
1) The same number of drive objects
2) The same drive objects
In this sense, they are consistent.
Difference between p0101 and p0978:
p0978 can be re-sorted and a zero inserted in order to identify those drive objects that participate in the process
data exchange and to define their sequence in the process data exchange. Drive objects that are listed after the
first zero, are excluded from the process data exchange.
For p0978, in addition, the value 255 can be inserted a multiple number of times.
p0978[n] = 255 means: The drive object is visible for the PROFIBUS master and is empty (without any actual pro-
cess data exchange). This allows cyclic communications of a PROFIBUS master with unchanged configuring to the
drive units with a lower number of drive objects.
Dependency:
Refer to: p0101, p0971, p0977
Note:
p0978 cannot be changed when the drive system is first commissioned. The reason for this is that at this time the
actual topology has still not been acknowledged (p0099 is still not equal to r0098 and p0009 is set to 0).
p0978[0...16]
List of drive objects / List of the DO
CU_CX32, CU_S
Can be changed:
C1(1)
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 255
[0]
1
[1] 0
[2] 0
[3] 0
[4] 0
[5] 0
[6] 0
[7] 0
[8] 0
[9] 0
[10] 0
[11] 0
[12] 0
[13] 0
[14] 0
[15] 0
[16] 0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...