![Siemens SINAMICS S Series Скачать руководство пользователя страница 886](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427886.webp)
Parameters
List of parameters
1-886
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the GUIDs of OA applications installed on the CompactFlash card.
r4959[0...15]: GUID of OA application 1
r4960[16]: Major information of OA application 1
r4960[17]: Minor information of OA application 1
r4959[18...33]: GUID of OA application 2
r4960[34]: Major information of OA application 2
r4960[35]: Minor information of OA application 2
etc.
Dependency:
Refer to: r4950, r4951, r4952, r4955, p4956, r4957, r4958, r4960
Notice:
If there is no OA application, then it is not possible to access an index.
Description:
Displays the GUIDs of this drive object of the OA applications installed on the CompactFlash card.
r4960[0...15]: GUID of this drive object of OA application 1
r4960[16]: Major information of this drive object of OA application 1
r4960[17]: Minor information of this drive object of OA application 1
r4960[18...33]: GUID of this drive object of OA application 2
r4960[34]: Major information of this drive object of OA application 2
r4960[35]: Minor information of this drive object of OA application 2
etc.
Dependency:
Refer to: r4950, r4951, r4952, r4955, p4956, r4957, r4958, r4959
Notice:
If there is no OA application, then it is not possible to access an index.
Description:
Displays the active power units for a parallel circuit configuration.
Dependency:
Refer to: p7001
r4959[0...n]
OA application GUID / OA appl GUID
All objects
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dynamic index:
r4952
Func. diagram:
-
P-Group:
OEM range
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4960[0...n]
OA application GUID drive object / OA appl GUID DO
All objects
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned8
Dynamic index:
r4952
Func. diagram:
-
P-Group:
OEM range
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r7000
Par_circuit No. of active power units / Qty active PU
A_INF (Parallel),
B_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Modulation
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...