List of parameters
Parameters
1-619
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the minimum limiting of the technology controller.
Dependency:
Refer to: p2292
Description:
Displays the status word of the technology controller.
Description:
Sets the signal source to select the "staging" function.
Description:
Sets the assigned encoder.
The actual value preprocessing and the closed-loop position control are carried out using the assigned encoder.
Values:
0:
No encoder
1:
Encoder 1
2:
Encoder 2
3:
Encoder 3
Dependency:
Refer to: p0187, p0188, p0189
Notice:
For the setting p2502 = 0 (no encoder), closed-loop position control is not possible. This setting is only practical as
supportive measure to implement sensorless closed-loop speed control (e.g. if the motor encoder is defective).
p2298[0...n]
CI: Technology controller minimum limiting / Tec_ctrl min_lim
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2292[0]
r2349.0...3
CO/BO: Technology controller status word / Tec_ctrl stat word
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Technology controller de-activated
Yes
No
-
01
Technology controller limited
Yes
No
-
02
Technology controller, motorized potentiom-
eter limited max.
Yes
No
-
03
Technology controller, motorized potentiom-
eter limited min.
Yes
No
-
p2369
BI: Staging control word / Staging STW
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2502[0...n]
LR encoder assignment / Encoder assignment
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
C2(25)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
DDS, p0180
Func. diagram:
4010
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 3
1
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...