List of faults and alarms
Faults and Alarms
3-1561
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
F07552 (A)
Drive encoder: Encoder configuration not supported
Drive object:
SERVO, VECTOR
Reaction:
OFF2 (IASC / DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The requested encoder configuration is not supported. Only bits may be requested in p0404 that are signaled as
being supported by the encoder evaluation in r0456.
Fault value (r0949, interpret decimal):
Low word low byte: Encoder data set number
Low word high byte: Component number
High word:
The encoder evaluation does not support a function selected in p0404.
1: sin/cos encoder with absolute track (this is supported by SME25).
3: Squarewave encoder (this is supported by SMC30).
4: sin/cos encoder (this is supported by SMC20, SMI20, SME20, SME25).
12: sin/cos encoder with reference mark (this is supported by SME20).
15: Commutation with zero mark for separately-excited synchronous motors with VECTORMV.
23: Resolver (this is supported by SMC10, SMI10).
65535: Other function (compare r0456 and p0404).
See also: p0404 (Encoder configuration effective), r0456 (Encoder configuration supported)
Remedy:
- check the encoder parameterization (p0400, p0404).
- use the matching encoder evaluation (r0456).
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07553 (A)
Drive encoder: Sensor Module configuration not supported
Drive object:
SERVO, VECTOR
Reaction:
OFF2 (IASC / DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The Sensor Module does not support the requested configuration.
Possible causes:
- bits are set in p0430 (requested functions) that are not set in r0458 (supported functions). This does not apply for
bit 19 (safety position actual value sensing), bit 29 (phase correction), bit 30 (amplitude correction) and bit 31 (offset
correction).
- p1982 > 0 (pole position identification requested), but r0458 bit 16 = 0 (pole position identification not supported).
Fault value (r0949, interpret binary):
DCBA:
A: Encoder Data Set number.
B: First incorrect bit.
Remedy:
- check the encoder parameterization (p0430).
- check the pole position identification routine (p1982).
- use the matching encoder evaluation (r0458).
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07555 (A)
Drive encoder: Configuration position tracking
Drive object:
SERVO, VECTOR
Reaction:
OFF2 (IASC / DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The configuration of the position tracking is not supported.
Position tracking can only be activated for absolute encoders.
For linear axes, it is not possible to simultaneously activate the position tracking for load- and measuring gearboxes.
Fault value (r0949, interpret decimal):
Low word low byte: Encoder data set number
Low word high byte: Component number
High word low byte: Data set number (only load gearboxes)
High word high byte: Cause
0: An absolute encoder is not being used.
1 : Position tracking cannot be activated because the internal NVRAM is full or the Control Unit does not have an
NVRAM.
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...