![Siemens SINAMICS S Series Скачать руководство пользователя страница 776](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427776.webp)
Parameters
List of parameters
1-776
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice:
For the BICO interconnection of the connector output (CO) only bit 00 ... bit 15 are transferred.
Note:
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the inverted status of the digital inputs of the Terminal Board 30 (TB30).
Dependency:
Refer to: r4022
Note:
DI: Digital input
Description:
Displays the inverted status of the digital inputs of terminal module 31 (TM31).
Dependency:
Refer to: r4022
Note:
DI: Digital input
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the inverted status of the digital inputs of terminal module 41 (TM41).
r4023.0...3
BO: TB30 digital inputs, status inverted / TB30 DI status inv
TB30
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
1790, 9100
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X481.1)
High
Low
-
01
DI 1 (X481.2)
High
Low
-
02
DI 2 (X481.3)
High
Low
-
03
DI 3 (X481.4)
High
Low
-
r4023.0...11
CO/BO: TM31 digital inputs, status inverted / TM31 DI status inv
TM31
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
1840, 9550,
9552, 9560, 9562
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X520.1)
High
Low
-
01
DI 1 (X520.2)
High
Low
-
02
DI 2 (X520.3)
High
Low
-
03
DI 3 (X520.4)
High
Low
-
04
DI 4 (X530.1)
High
Low
-
05
DI 5 (X530.2)
High
Low
-
06
DI 6 (X530.3)
High
Low
-
07
DI 7 (X530.4)
High
Low
-
08
DI/DO 8 (X541.2)
High
Low
-
09
DI/DO 9 (X541.3)
High
Low
-
10
DI/DO 10 (X541.4)
High
Low
-
11
DI/DO 11 (X541.5)
High
Low
-
r4023.0...11
BO: TM41 digital inputs, status inverted / TM41 DI status inv
TM41
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...