![Siemens SINAMICS S Series Скачать руководство пользователя страница 805](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427805.webp)
List of parameters
Parameters
1-805
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the enable signal of the analog inputs of terminal module 31 (TM31).
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description:
Sets the signal source for the enable signal of the analog input of terminal module 41 (TM41).
Index:
[0] = AI 0 (X523.1/X523.2)
Description:
Sets the signal source for the analog outputs of the Terminal Board 30 (TB30).
Index:
[0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Note:
AO: Analog Output
Description:
Sets the signal source for the analog outputs of terminal module 31 (TM31).
Index:
[0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Note:
AO: Analog Output
p4069[0...1]
BI: TM31 analog inputs, signal source for enable / TM31 AI enable
TM31
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9566, 9568
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p4069[0...0]
BI: TM41 analog input, signal source for enable / TM41 AI enable
TM41
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9663
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p4071[0...1]
CI: TB30 analog outputs, signal source / TB30 AO sig_source
TB30
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
1790, 9106
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4071[0...1]
CI: TM31 analog outputs, signal source / TM31 AO sig_source
TM31
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
1840, 9572
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...