Parameters
List of parameters
1-1014
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
5:
Sets the stop response via p9563 (SLS-specific)
10:
STOP A with delayed pulse cancelation when the bus fails
11:
STOP B with delayed pulse cancelation when the bus fails
12:
STOP C with delayed pulse cancelation when the bus fails
13:
STOP D with delayed pulse cancelation when the bus fails
14:
STOP E with delayed pulse cancelation when the bus fails
Dependency:
Refer to: p9531, p9563, p9580
Note:
A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed / SG: Safely reduced speed
Description:
Sets the stop response for the function "Safely-Limited Position" (SLP).
Values:
2:
STOP C
3:
STOP D
4:
STOP E
Dependency:
Refer to: p9534, p9535
Note:
A change only becomes effective after a POWER ON.
SLP: Safely-Limited Position / SE: Safe software limit switches
Description:
Sets the SLS-specific stop response for the function "Safely-Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Values:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
10:
STOP A with delayed pulse cancelation when the bus fails
11:
STOP B with delayed pulse cancelation when the bus fails
12:
STOP C with delayed pulse cancelation when the bus fails
13:
STOP D with delayed pulse cancelation when the bus fails
14:
STOP E with delayed pulse cancelation when the bus fails
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency:
Refer to: p9531, p9561, p9580
Notice:
Values 10 to 14 are being prepared and are presently ineffective.
p9562
SI motion SLP (SE) stop response (Control Unit) / SI Mtn SLP resp
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
2 4
2
p9563[0...3]
SI motion SLS (SG)-specific stop response (Control Unit) / SI Mtn SLS stop
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 14
2
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...