Parameters
List of parameters
1-856
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the status of the incremental encoder emulation on terminal module 41 (TM41).
Description:
Displays the actual operating mode of Terminal Module 41 (TM41).
Dependency:
Refer to: p4400
Description:
Sets the signal source for the position actual value.
Dependency:
Refer to: p4400, r4403
Note:
Prerequisites for the signal source:
For the incremental encoder emulation, an encoder is required that supplies precisely one zero mark per revolution.
The following BICO interconnection should be preferably set: CI: p4420 = r0479.
An encoder actual value (r0479) can only be interconnected once on a TM41.
The zero mark of the incremental encoder is output at the encoder interface after successful internal, automatic
synchronization.
If an absolute encoder is connected to the TM41, then a zero mark is always output at the zero revolution at the
encoder interface of the TM41. The same behavior applies even if no encoder parameter is interconnected.
Description:
This factor defines the multiplier in which the encoder position setpoint of the incremental encoder emulation is
shifted depending on the velocity.
r4402.0...2
CO/BO: TM41 incremental encoder emulation, status / Enc_emulat status
TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
9674, 9676
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Zero mark enabled
Yes
No
-
01
Tracks A/B enabled
Yes
No
-
02
Interface encoder emulation enabled
Yes
No
-
r4403
Incremental encoder emulation mode active / Enc_emul mode act
TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
9674, 9676
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p4420
CI: TM41 incremental encoder emulation encoder position actual value /
Enc_emul s_act
TM41
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
9676
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4421
TM41 incremental encoder emulation deadtime compensation / Enc_emul t_dead
TM41
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9676
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-10.00 10.00
0.00
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...