![Siemens SINAMICS S Series Скачать руководство пользователя страница 678](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427678.webp)
Parameters
List of parameters
1-678
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the effective force setpoint when reaching the fixed stop (referred to CI: p1522, CI: p1523).
Dependency:
Refer to: p1520, p1521, p1522, p1523, r2676
Description:
Sets a fixed setpoint for the position.
Dependency:
Refer to: p2642, p2648
Note:
As standard, the following BICO interconnection is established: CI: p2642 = r2690
Description:
Sets a fixed setpoint for the velocity.
Dependency:
Refer to: p2643
Note:
As standard, the following BICO interconnection is established: CI: p2643 = r2691
Description:
Sets a fixed setpoint for the acceleration override.
Dependency:
Refer to: p2572, p2644
Note:
As standard, the following BICO interconnection is established: CI: p2644 = r2692
The percentage value refers to the maximum acceleration (p2572).
r2687
CO: EPOS force setpoint / F_set
SERVO (EPOS, Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3616, 3617
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [N]
- [N]
- [N]
p2690
CO: EPOS position fixed setpoint / Pos fixed value
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
0 [LU]
p2691
CO: EPOS velocity fixed setpoint / v fixed value
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 [1000 LU/min]
40000000 [1000 LU/min]
600 [1000 LU/min]
p2692
CO: EPOS acceleration override, fixed setpoint / a_over fixed val
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.100 [%]
100.000 [%]
100.000 [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...