![Siemens SINAMICS S Series Скачать руководство пользователя страница 286](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427286.webp)
Parameters
List of parameters
1-286
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[7] = Reserved
[8] = Reserved
[9] = Reserved
[10] = Reserved
Note:
Information about the individual indices can be taken from the following literature:
PROFIdrive Profile Drive Technology
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0981, r0989
Note:
The existing parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here. In
a long list, index 99 contains the parameter number at which position the list continues.
This list completely comprises the following parameters:
r0980[0...99], r0981[0...99] ... r0989[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0980, r0989
Note:
The existing parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here. In
a long list, index 99 contains the parameter number at which position the list continues.
This list completely comprises the following parameters:
r0980[0...99], r0981[0...99] ... r0989[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0980[0...199]
List of existing parameters 1 / List avail par 1
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, DMC20,
SERVO, S_INF,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r0981[0...199]
List of existing parameters 2 / List avail par 2
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, DMC20,
SERVO, S_INF,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41, VEC-
TOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...