PROFIdrive
F
u
nct
ion
D
iag
ra
m
s
2
-11
55
© Siemens AG 2
007 All Rights Reserved
SINAMICS
S List Manual (LH1
), 07/200
7
Fi
gure 2-4
7
2
442 – STW
1
control word
in
te
rco
nne
ctio
n (p203
8 = 0)
- 2442 -
Function diagram
8
7
6
5
4
3
2
1
fp_2442_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
14.07.06 V02.05.00
PROFIdrive - STW1 control word interconnection (p2038 = 0)
<1> Used in telegrams 1, 2, 3, 4, 5, 6, 7, 110, 352.
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
STW1.5
STW1.6
STW1.8
STW1.9
STW1.11
STW1.12
STW1.13
STW1.14
STW1.15
STW1.7
STW1.10
p0848[0] = r2090.2
p0852[0] = r2090.3
p1140[0] = r2090.4
p1141[0] = r2090.5
p1142[0] = r2090.6
p2103[0] = r2090.7
-
-
p0854[0] = r2090.10
p1113[0] = r2090.11
-
p1035[0] = r2090.13
p1036[0] = r2090.14
-
p0840[0] = r2090.0
p0844[0] = r2090.1
= ON (pulses can be enabled)
0 = OFF1
(braking with ramp-function generator, then pulse cancellation and ready-to-power-up)
1 = No OFF2
(enable is possible)
0 = OFF2 (immediate pulse cancellation and power-on inhibit)
1 = No OFF3
(enable possible)
0 = OFF3 (braking with the OFF3 ramp p1135, then pulse cancellation and power-on inhibit)
1 = Enable operation
(pulses can be enabled)
0 = Inhibit operation (cancel pulses)
1 = Operating condition
(the ramp-function generator can be enabled)
0 = inhibit ramp-function generator (set the ramp-function generator output to zero)
1 = Enable the ramp-function generator
0 = stop the ramp-function generator (freeze the ramp-function generator output)
1 = Enable setpoint
0 = inhibit setpoint (set the ramp-function generator input to zero)
= Acknowledge faults
Reserved
Reserved
1 = Control via PLC
1 = Dir of rot reversal
Reserved
1 = Motorized potentiometer, setpoint, raise
Reserved
1 = Motorized potentiometer, setpoint, lower
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2501.3]
[2546.1]
-
-
[2501.3]
[2505.3]
-
[2505.3]
[2505.3]
-
[2501.3]
[2501.3]
Signal targets for STW1 in Interface Mode SINAMICS (p2038 = 0)
[2610]
[2610]
[3060] [3070] [3080]
[3060] [3070]
[3060] [3070] [3080]
[8060]
-
-
[2501]
[3040]
-
[3020]
[3020]
-
[2610]
[2610]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Signal
Interconnection
parameters
Meaning
[Function diagram]
internal control word
[Function diagram]
signal target
Inverted
<2>
<1>
<3> Only for "expanded setpoint channel" and "extended ramp-function generator"
<3>
<3>
<3>
Refer to [1020.7]
PROFIdrive sampling time
<2> Bit 10 must be set in the first PZD word of the telegram received from PROFIBUS in order to ensure that the drive accepts the process data.
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...