![Siemens SINAMICS S Series Скачать руководство пользователя страница 331](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427331.webp)
List of parameters
Parameters
1-331
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the position deviation XERR for DSC (position controller output of the higher-level con-
trol).
Dependency:
Clock cycle synchronous operation must be activated for DSC.
The position controller gain factor (KPC), the position deviation (XERR) and the speed setpoint (N_SOLL_B) must
be included in the setpoint telegram.
At least the encoder interface (Gx_XIST1) must be included in the actual value telegram.
The position actual value used for the internal position controller can be selected using p1192.
Refer to: p1191, p1192
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
DSC: Dynamic Servo Control
Description:
Sets the signal source for the position controller gain KPC for DSC.
Dependency:
Clock cycle synchronous operation must be activated for DSC.
Refer to: p1190
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
DSC: Dynamic Servo Control
Description:
Sets the number of the encoder used for DSC.
Values:
1:
Encoder 1 (motor encoder)
2:
Encoder 2
3:
Encoder 3
Note:
DSC: Dynamic Servo Control
Value 1 corresponds to encoder 1 (motor encoder); the encoder data set is assigned via p0187.
Value 2 corresponds to encoder 2; the encoder data set is assigned via p0188.
Value 3 corresponds to encoder 3; the encoder data set is assigned via p0189.
p1190
CI: DSC position deviation XERR / DSC XERR
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
1550, 3090
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p1191
CI: DSC position controller gain KPC / DSC KPC
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
1550, 3090
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p1192[0...n]
DSC enc selection / DSC enc selection
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
DDS, p0180
Func. diagram:
3090
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 3
1
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...