Description:
After power-on, binector output r9935.0 is set with the start of the first sampling time and is again reset after approx.
100 ms.
Description:
Setting to control the runtime measurement.
Values:
0:
Stop runtime measurement
1:
Start runtime meas (internal)
2:
Clear trace buffer (internal)
3:
Activate calculation of remaining computing time
Dependency:
Refer to: r9976
Description:
Displays the system load.
The system load measurement is automatically started after run-up.
The individual values (computation load and cyclic load) are measured over short time slices and from the mea-
surements, the maximum, the minimum and the average value are formed and displayed in the appropriate indices.
Further, the degree of memory utilization of the data and program memory is displayed.
Index:
[0] = comp. time load (min)
[1] = Computation time load (averaged)
[2] = Computation time load (max)
[3] = Computation time load cyclic (min)
[4] = Computation time load cyclic (avg)
[5] = Computation time load cyclic (max)
[6] = Data memory locked
[7] = Program memory locked
Dependency:
Refer to: p9950
Refer to: A01053
r9935.0
BO: POWER ON delay signal / POWER ON t_delay
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
POWER ON delay signal
High
Low
-
p9950
Runtime measurement control / Runtime_meas ctrl
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 3
0
r9976[0...7]
System load / Sys_load
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...