List of parameters
Parameters
1-409
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the upper adaptation speed of the speed controller. No adaptation is effective above this speed.
For P gain, p1460 * p1461 is effective. For the integral time, p1462 * p1463 is effective.
Dependency:
Refer to: p1460, p1461, p1462, p1463, p1464
Description:
Sets the upper adaptation velocity of the velocity controller. No adaptation is effective above this velocity.
For P gain, p1460 * p1461 is effective. For the integral time, p1462 * p1463 is effective.
Dependency:
Refer to: p1460, p1461, p1462, p1463, p1464
Description:
Sets the upper adaptation speed of the speed controller. No adaptation is effective above this speed.
For P gain, p1460 * p1461 is effective. For the integral time, p1462 * p1463 is effective.
Dependency:
Refer to: p1460, p1461, p1462, p1463, p1464
Note:
If the upper transition point p1465 of the speed controller adaptation is set to values less than the lower transition
point p1464, then the controller below p1465 is adapted with p1461 or p1463. This means that an adaptation can
be implemented for low speeds without having to change the controller parameters.
Description:
Sets the signal source for the scaling of the P gain of the speed controller. This also makes the effective P gain
(including adaptations) scalable.
p1465[0...n]
Speed controller adaptation speed, upper / n_ctrl n upper
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5050
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
210000.00 [RPM]
210000.00 [RPM]
p1465[0...n]
Velocity controller adaptation velocity, upper / v_ctrl n upper
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5050
P-Group:
Closed-loop control
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [m/min]
1000.00 [m/min]
1000.00 [m/min]
p1465[0...n]
Speed controller adaptation speed, upper / n_ctrl n upper
VECTOR (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
6050
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
210000.00 [RPM]
210000.00 [RPM]
p1466[0...n]
CI: Speed controller P-gain scaling / n_ctrl Kp scal
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
5050
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...