Parameters
List of parameters
1-974
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the monitoring clock cycle for safe motion monitoring.
Dependency:
Refer to: p0115, p9500
Refer to: F01652
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The monitoring clock cycle must be a multiple of the position controller clock cycle.
Description:
Sets the enable signals for the safe motion monitoring.
Dependency:
Refer to: p9501
Refer to: F01682, F01683
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SOS: Safe Operational Stop
SLS: Safely Limited Speed
Description:
Sets the axis type (linear axis or rotary axis/spindle).
Values:
0:
Linear axis
1:
Rot axis/spindle
Dependency:
Refer to: p9502
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For the commissioning software, after changing over the axis type, the units dependent on the axis type are only
updated after a project upload.
A change only becomes effective after a POWER ON.
p9300
SI motion monitoring clock cycle (Motor Module) / SI Mtn clock MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
500.00 [µs]
25000.00 [µs]
12000.00 [µs]
p9301
SI motion enable safety functions (Motor Module) / SI Mtn enable MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable SOS/SLS
Enable
Inhibit
-
03
Enable actual value synchronization
Enable
Inhibit
-
p9302
SI motion axis type (Motor Module) / SI Mtn AxisType MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...