List of parameters
Parameters
1-919
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
0: There are not parameter changes to save.
1: There are parameter changes to save.
Index 8:
Drive object changeover of units. When changing reference or changeover parameters (e.g. p2000, p0304 ...), the
value in this index is incremented.
Index 9:
Drive object parameter count. When changing the number of parameters by loading Drive Control Chart (DCC), the
value in this index is incremented.
Index:
[0] = Sum of the following indices
[1] = r0107 or r0108
[2] = Drive object name (p0199)
[3] = Structure-relevant parameters (e.g. p0180)
[4] = BICO interconnections
[5] = Activate/de-activate drive object
[6] = Data back-up required
[7] = Reserved
[8] = Reference or changeover parameters (e.g. p2000)
[9] = Parameter count through Drive Control Chart (DCC)
Dependency:
Refer to: r7868, r7870
Description:
Displays the configuration changes on the drive object.
Index 0:
When changing one of the following indices, then the value in this index is incremented.
Index 1:
Drive object configuration. When changing p10, p0107 or p108, the value in this index is incremented.
Index 2:
Drive object name. When changing p0199, the value in this index is incremented.
Index 3:
Drive object structure. When changing a parameter that is relevant for the structure (e.g. number of data sets), the
value in this index is incremented.
Index 4:
Drive object BICO interconnections. When changing r3977, the value in this index is incremented.
Index 6:
Drive object, data save.
0: There are not parameter changes to save.
1: There are parameter changes to save.
Index 8:
Drive object changeover of units. When changing reference or changeover parameters (e.g. p2000, p0304 ...), the
value in this index is incremented.
Index 9:
Drive object parameter count. When changing the number of parameters by loading Drive Control Chart (DCC), the
value in this index is incremented.
Index:
[0] = Sum of the following indices
[1] = p0010, r0107 or r0108
[2] = Drive object name (p0199)
[3] = Structure-relevant parameters (e.g. p0180)
[4] = BICO interconnections
[5] = Activate/de-activate drive object
[6] = Data back-up required
r7871[0...9]
Configuration changes drive object / Config_chng DO
A_INF, B_INF,
S_INF
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...