Parameters
List of parameters
1-342
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Re bit 00:
Status to display the single initialization after POWER ON.
Re bit 01:
State in which the automatic restart function waits for faults (initial state).
Re bit 02:
General display that a fault has been identified and that the restart or acknowledgement has been initiated.
Re bit 03:
Displays the acknowledge command within the "acknowledge alarms" status (bit 4 = 1). For bit 5 = bit 6 = 1, the
acknowledge command is continually displayed.
Re bit 04:
State in which the faults that are present are acknowledged. The status is exited again after successful acknowl-
edgement. A change is only made into the next state if it is signaled that a fault is no longer present after an
acknowledgement command (bit 3 = 1).
Re bit 05:
State in which the drive is automatically powered-up (only for p1210 = 4, 6).
Re bit 06:
State in which the system waits after having been powered-up, to the end of the start attempt (to the end of the
magnetization process).
For p1210 = 1, this signal is directly set after the faults have been successfully acknowledged.
Re bit 07:
State, which is assumed after a fault occurs within the automatic restart function.
Re bits 12 ... 15:
Actual state of the start counter (binary coded).
Description:
Sets the holding brake configuration.
Values:
0:
No motor holding brake being used
1:
Motor holding brake acc. to sequence control
2:
Motor holding brake always open
3:
Motor holding brake like sequence control, connection via BICO
Dependency:
Refer to: p1216, p1217, p1226, p1227, p1228, p1278
Caution:
For the setting p1215 = 0, if a brake is used, it remains closed. If the motor moves, this will destroy the brake.
Notice:
If p1215 was set to 1 or if p1215 was set to 3, then when the pulses are canceled, the brake is closed even if the
motor is still rotating. Pulse cancelation can either be caused by a 0 signal at p0844, p0845 or p0852 or as a result
of a fault with OFF2 response. If this is not desirable (e.g. for a flying restart), then the brake can be kept open using
a 1 signal at p0855.
Note:
If the configuration is set to "no holding brake present" when booting, then the motor holding brake will be automat-
ically identified. If a motor holding brake is detected, the configuration is set to "motor holding brake as for sequence
control".
If a holding brake integrated in the motor is used, then it is not permissible that p1215 is set to 3.
if an external motor holding brake is being used, then p1215 should be set to 3 and r0899.12 should be intercon-
nected as control signal.
When the function module "extended brake control" is activated (r0108.14 = 1), r1229.1 should be interconnected
as control signal.
The parameter can only be set to zero when the pulses are inhibited.
13
Start count. bit 1
On
Off
-
14
Start count. bit 2
On
Off
-
15
Start count. bit 3
On
Off
-
p1215
Motor holding brake configuration / Brake config
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
-
Func. diagram:
2701, 2707,
2711
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 3
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...