Parameters
List of parameters
1-752
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the v coordinate of the 10th value pair of the friction characteristic.
Dependency:
Refer to: p3839, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 1st value pair of the friction characteristic.
Dependency:
Refer to: p3820, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 1st value pair of the friction characteristic.
Dependency:
Refer to: p3820, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 2nd value pair of the friction characteristic.
Dependency:
Refer to: p3821, p3845
p3829[0...n]
Friction characteristic, value v9 / Friction v9
SERVO (Lin)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [m/min]
21000.00 [m/min]
300.00 [m/min]
p3830[0...n]
Friction characteristic, value M0 / Friction M0
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-1000000.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
p3830[0...n]
Friction characteristic, value F0 / Friction F0
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
8_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-1000000.00 [N]
1000000.00 [N]
0.00 [N]
p3831[0...n]
Friction characteristic, value M1 / Friction M1
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-1000000.00 [Nm]
1000000.00 [Nm]
0.00 [Nm]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...