Parameters
List of parameters
1-628
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the actual position actual value determined by the position actual value preprocessing.
Index:
[0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency:
Refer to: p2502, r2526
Note:
r2526.0 = 1 --> The position actual value in r2521[0] for the position control is valid.
r2527.0 = 1 --> The position actual value in r2521[1] for encoder 1 is valid.
r2528.0 = 1 --> The position actual value in r2521[2] for encoder 2 is valid.
r2529.0 = 1 --> The position actual value in r2521[3] for encoder 3 is valid.
Description:
Displays the velocity actual value determined by the position actual value preprocessing.
Index:
[0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency:
Refer to: p2502, r2526
Note:
r2526.0 = 1 --> The velocity actual value in r2522[0] for the position control is valid.
r2527.0 = 1 --> The velocity actual value in r2522[1] for encoder 1 is valid.
r2528.0 = 1 --> The velocity actual value in r2522[2] for encoder 2 is valid.
r2529.0 = 1 --> The velocity actual value in r2522[3] for encoder 3 is valid.
Description:
Displays the value determined by the function "reference mark search" and "measuring probe evaluation".
Index:
[0] = Closed-loop position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Encoder 3
Dependency:
Refer to: p2502, r2526
r2521[0...3]
CO: LR position actual value / s_act
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
4010
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2522[0...3]
CO: LR velocity actual value / v_act
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
4010
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [1000 LU/min]
- [1000 LU/min]
- [1000 LU/min]
r2523[0...3]
CO: LR measured value / Measured value
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
4010
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...