List of faults and alarms
Faults and Alarms
3-1569
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
A07594 (F)
Encoder 2: Overflow of the value range for the position actual value
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The value range (-2147483648 ... 2147483647) for the position actual value representation was exceeded.
When the overflow occurs, the status "referenced" or the status "adjustment absolute measuring system" is reset.
Fault value (r0949, interpret decimal):
1: r2521 has exceeded the value range for the position actual value display.
2: r0483 and/or r2723 has exceeded the value range for the position actual value display.
3. The factor to convert the absolute position (r0483 and/or r2723) from increments to LUs is greater than 1.0.
Remedy:
If required, reduce the traversing range or position resolution.
Reducing the position resolution and conversion factor (supplementary info 3):
- reduce p2506 (LUs per load revolution for rotary encoders)
- increase p419 (fine resolution of absolute position actual values).
Reaction upon F:
OFF1 (OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY
A07595 (F)
Encoder 3: Overflow of the value range for the position actual value
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The value range (-2147483648 ... 2147483647) for the position actual value representation was exceeded.
When the overflow occurs, the status "referenced" or the status "adjustment absolute measuring system" is reset.
Fault value (r0949, interpret decimal):
1: r2521 has exceeded the value range for the position actual value display.
2: r0483 and/or r2723 has exceeded the value range for the position actual value display.
3. The factor to convert the absolute position (r0483 and/or r2723) from increments to LUs is greater than 1.0.
Remedy:
If required, reduce the traversing range or position resolution.
Reducing the position resolution and conversion factor (supplementary info 3):
- reduce p2506 (LUs per load revolution for rotary encoders)
- increase p419 (fine resolution of absolute position actual values).
Reaction upon F:
OFF1 (OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY
A07596 (F)
Encoder 1: Reference function interrupted
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
An activated reference function (reference mark search or measuring probe evaluation) was interrupted.
- an encoder fault has occurred (Gn_ZSW.15 = 1).
- position actual value was set during an activated reference function.
- simultaneously activate reference mark search and measuring probe evaluation (BI: p2508 and BI: p2509 = 1 sig-
nal).
- activated reference function (reference mark search or measuring probe evaluation) was de-activated (BI: p2508
and BI: p2509 = 0 signal).
Remedy:
- check the causes and resolve.
- reset the control (BI: p2508 and BI: p2509 = 0 signal) and activate the requested function.
Reaction upon F:
OFF1 (OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...