![Siemens SINAMICS S Series Скачать руководство пользователя страница 692](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427692.webp)
Parameters
List of parameters
1-692
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Proportional gain of the flux controller set from the motor identification.
Note:
For synchronous motors, this parameters has no effect.
Description:
Integral action time of the flux controller set from the motor identification.
Note:
For synchronous motors, this parameters has no effect..
Description:
Proportional gain of the current controller set from the motor identification.
Description:
Integral action time of the current controller set from the motor identification.
Description:
Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
p3080
Motor identification - flux controller P gain / MotId flux ctrl Kp
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
0.0 [A/Vs]
999999.0 [A/Vs]
0.0 [A/Vs]
p3081
Motor identification - flux controller integral action time / MotId flux ctrl Tn
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p3082
Motor identification - current controller P gain / MotId I_ctrl Kp
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
18_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 [V/A]
100000.000 [V/A]
0.000 [V/A]
p3083
Motor identification - current controller integral action time / MotId I_ctrl Tn
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
1000.00 [ms]
0.00 [ms]
p3100
RTC time stamp mode / RTC t_stamp mode
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...