Parameters
List of parameters
1-76
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the actual torque value.
Dependency:
Refer to: r0031
Note:
The torque actual value is available smoothed (r0031) and unsmoothed (r0080).
Description:
Displays the actual force value.
Dependency:
Refer to: r0031
Note:
The force actual value is available smoothed (r0031) and unsmoothed (r0080).
Description:
Displays the actual torque value.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Refer to: r0031
Note:
The torque actual value is available smoothed (r0031 with 100 ms, r0080[1] with p0045) and unsmoothed
(r0080[0]).
Description:
Displays the torque utilization as a percentage.
The torque utilization is obtained from the required smoothed torque referred to the torque limit.
Dependency:
Refer to: r0033
Note:
The torque utilization is available smoothed (r0033) and unsmoothed (r0081).
The torque utilization is obtained from the required torque referred to the torque limit as follows:
- Positive torque: r0081 = ((r0079 + r1532) / (r1538 - r1532)) * 100 %
- Negative torque: r0081 = ((-r0079 + r1532) / (-r1539 + r1532)) * 100 %
r0080
CO: Torque actual value / M_act
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5730
P-Group:
Displays, signals
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r0080
CO: Force actual value / F_act
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5730
P-Group:
Displays, signals
Units group:
8_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [N]
- [N]
- [N]
r0080[0...1]
CO: Torque actual value / M_act
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
6714, 6799
P-Group:
Displays, signals
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r0081
CO: Torque utilization / M_Utilization
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8012
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...