![Siemens SINAMICS S Series Скачать руководство пользователя страница 900](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427900.webp)
Parameters
List of parameters
1-900
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the measured actual value of phase V as peak value.
The summed value of all power units is displayed in r0069[1].
Description:
Displays the measured actual value of phase W as peak value.
The summed value of all power units is displayed in r0069[2].
Description:
Displays the measured offset of phase U as peak value.
The summed value of all power units is displayed in r0069[3].
Description:
Displays the measured offset of phase V as peak value.
The summed value of all power units is displayed in r0069[4].
Description:
Displays the measured offset of phase W as peak value.
The summed value of all power units is displayed in r0069[5].
r7224[0...n]
CO: Par_circuit phase current actual value phase V / I_phase V act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7225[0...n]
CO: Par_circuit phase current actual value phase W / I_phase W act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7226[0...n]
CO: Par_circuit phase current actual value phase U offset / I_phase U offset
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7227[0...n]
CO: Par_circuit phase current actual value phase V offset / I_phase V offset
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7228[0...n]
CO: Par_circuit phase current actual value phase W offset / I_phase W offset
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...