![Siemens SINAMICS S Series Скачать руководство пользователя страница 862](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427862.webp)
Parameters
List of parameters
1-862
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values:
0:
Measurement function inactive
1:
Measuring function, parameterization checked
2:
Measuring function waits for stabilizing time
3:
Measuring function recording (tracing)
4:
Measuring function, trace ended with error
5:
Measuring function, trace successfully completed
Description:
Displays the required memory in bytes for the actual parameterization.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
Description:
Sets the trigger condition for the trace.
Values:
1:
Immediate start
2:
Positive edge
3:
Negative edge
4:
Entry to hysteresis band
5:
Leaving hysteresis band
6:
Trigger at bit mask
7:
Start with function generator
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Selects the trigger signal for the trace.
OR: Defines the data type of signal to be traced when selected using the physical address (p4789).
r4706
Measuring function, status / Meas fct status
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
0 5
-
r4708[0...1]
Trace memory space required / Trace mem required
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
-
p4710[0...1]
Trace trigger condition / Trace Trig_cond
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
1 7
2
p4711[0...1]
Trace trigger signal / Trace trig_signal
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...