Description:
Enters the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p10063
Description:
Acknowledgement of the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency:
Refer to: p10062
Note:
The new password entered into p10062 must be re-entered in order to acknowledge.
p10062 = p10063 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
Description:
Displays the Safety Integrated version for the Terminal Module 54F (TM54F).
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
Dependency:
Refer to: r9390, r9590, r9770, r9870, r9890
Note:
Example:
r10090[0] = 2, r10090[1] = 3, r10090[2] = 1 --> SI version V02.03.01
Description:
Displays PROFINET Name of Station.
Notice:
An ASCII table (excerpt) can be found, for example, in the following List Manual:
p10062
SI password new TM54F / SI password new
TM54F_MA,
TM54F_SL
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2846
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p10063
SI password acknowledgement TM54F / SI ackn password
TM54F_MA,
TM54F_SL
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2846
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
r10090[0...2]
SI TM54F version / SI TM54F version
TM54F_MA,
TM54F_SL
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r61000[0...239]
PROFINET Name of Station / PN Name of Station
CU_S (PROFINET)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...