![Siemens SINAMICS S Series Скачать руководство пользователя страница 483](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427483.webp)
List of parameters
Parameters
1-483
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the power-on slip frequency for the Rs adaptation for the induction motor (ASM).
Description:
Displays the power-on stator frequency/ primary section frequency for the Lh adaptation for the induction motor
(ASM).
Description:
Displays the power-on slip frequency for the Lh adaptation for the induction motor (ASM).
Description:
Sets the smoothing time of the kT adaptation of the motor model for a permanent-magnet synchronous motor
(PEM).
Dependency:
Refer to: p1780, r1797
Description:
Sets the integral time of the kT adaptation of the motor model for a permanent-magnet synchronous motor (PEM).
r1790
Motor model Rs adaptation power-on slip / MotMod Rs fslip
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1791
Motor model Lh adaptation power-on frequency / MotMod Lh f_on
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1792
Motor model Lh adaptation power-on slip / MotMod Lh fslip
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
p1795[0...n]
Motor model kT adaptation smoothing time / MotMod kT T_smth
SERVO (Exp M_ctrl)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
1 [ms]
10000 [ms]
100 [ms]
p1795[0...n]
Motor model PEM kT adaptation integral time / MotMod kT Tn
VECTOR (n/M)
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
6731
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
10 [ms]
10000 [ms]
100 [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...