List of parameters
Parameters
1-417
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the parameterized total moment of inertia ((p0341 * p0342) + p1498) without evaluation by the scaling via
p1497.
Dependency:
Refer to: p1300, p1402, p1404, p1497
Note:
The parameterized total moment of inertia, taking into account p1497, influences the torque pre-control.
In sensorless operation or when the torque-speed pre-control with encoder (p1402.4 = 1) is activated, then torque-
speed pre-control is activated.
Description:
Displays the parameterized total weight ((p0341 * p0342) + p1498) without evaluation by the scaling via p1497.
Dependency:
Refer to: p1300, p1402, p1404, p1497
Note:
The parameterized total weight, taking into account p1497, influences the force-velocity pre-control in sensorless
operation or when activated, force-velocity pre-control with encoder (p1402.4).
Description:
Total moment of inertia without evaluation by scaling using p1497.
Description:
Sets the time constant of the PT1 filter for integrator feedback.
The integrator of the speed/velocity controller is re-parameterized to become a PT1 filter through a feedback ele-
ment (1st Order low pass filter characteristics).
The following applies:
p1494 < 0.25 (2 * p0115[1]) --> the PT1 filter is not active - the pure integrator is effective.
p1494 >= 0.25 (2 * p0115[1]) --> the PT1 filter is active and has replaced the pure integrator.
r1493
CO: Moment of inertia, total / Mom of inert total
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5042, 5210
P-Group:
Closed-loop control
Units group:
25_1
Unit selection:
p0100
Not for motor type:
FEM
Expert list:
1
Min Max
Factory
setting
- [kgm²]
- [kgm²]
- [kgm²]
r1493
CO: Load mass / Load mass
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5042, 5210
P-Group:
Closed-loop control
Units group:
27_1
Unit selection:
p0100
Not for motor type:
FEM
Expert list:
1
Min Max
Factory
setting
- [kg]
- [kg]
- [kg]
r1493
CO: Moment of inertia, total / Mom of inert total
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
6031
P-Group:
Closed-loop control
Units group:
25_1
Unit selection:
p0100
Not for motor type:
FEM
Expert list:
1
Min Max
Factory
setting
- [kgm²]
- [kgm²]
- [kgm²]
p1494[0...n]
Speed controller integrator feedback time constant / n_ctr integ_fdbk T
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5040, 5042,
5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
1000.00 [ms]
0.00 [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...