List of parameters
Parameters
1-1019
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
After starting, the appropriate parameters are copied from the Control Unit to the Motor Module.
After completing copying, parameters are automatically reset to 0.
Values:
0:
[00 hex] Copy function ended
29:
[1D hex] Start copy function node identifier
87:
[57 hex] Start copy function SI parameters
Note:
Re value = 57 hex:
The value can only be set if the safety commissioning mode is set and the Safety Integrated password was entered.
SI: Safety Integrated
Description:
Setting to transfer the reference checksums from the associated actual checksums after changes (SI parameters,
hardware).
After transferring the reference checksums, parameters are automatically reset to 0.
Values:
0:
[00 hex] Data unchanged
172:
[AC hex] Acknowledge data change complete
236:
[EC hex] Acknowledge hardware CRC
Dependency:
Refer to: r9398, p9399, r9728, p9729, r9798, p9799, r9898, p9899
Note:
Re value = AC hex:
The value can only be set if the safety commissioning mode is set and the Safety Integrated password was entered.
SI: Safety Integrated
Description:
Sets the signal source for the test stop of the safety-relevant motion monitoring functions.
Description:
Displays result list 1 that, for the data cross-check between the monitoring channels, led to the fault.
Index:
[0] = Result list, second channel
[1] = Result list, drive
p9701
Acknowledge SI motion data / Ackn SI Mtn dat
SERVO, TM54F_MA,
TM54F_SL, VEC-
TOR
Can be changed:
C2, U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
00EC hex
0000 hex
p9705
BI: SI Motion: Test stop signal source / SI Mtn test stop
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
r9710[0...1]
SI motion diagnostics result list 1 / SI Mtn res_list 1
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Actual value > upper limit SOS
Yes
No
-
01
Actual value > lower limit SOS
Yes
No
-
02
Actual value > upper limit, SE1
Yes
No
-
03
Actual value > lower limit, SE1
Yes
No
-
04
Actual value > upper limit, SE2
Yes
No
-
05
Actual value > lower limit, SE2
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...