![Siemens SINAMICS S Series Скачать руководство пользователя страница 497](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427497.webp)
List of parameters
Parameters
1-497
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Description:
Displays the identified rotor time constant.
Dependency:
Refer to: p1909, p1910, r1912, r1915, r1925, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951, p1952,
p1953
Description:
Displays the identified rotor time constant.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Description:
Displays the identified total leakage inductance.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
Description:
Displays the identified stator inductance.
Dependency:
Refer to: p1909, p1910, r1912, r1913, r1925, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951, p1952,
p1953
r1913
Rotor time constant identified / T_rotor ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r1913[0...2]
Identified rotor time constant / T_rotor ident
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r1914[0...2]
Identified total leakage inductance / L_total_leak ident
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r1915
Stator inductance identified / L_stator ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...