List of parameters
Parameters
1-1015
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed / SG: Safely reduced speed
Description:
Setting to select and de-select the acceptance test mode.
Values:
0:
[00 hex] De-select the acceptance test mode
172:
[AC hex] Select the acceptance test mode
Dependency:
Refer to: p9558, r9571
Refer to: C01799
Description:
Displays the status of the acceptance test mode.
Values:
0:
[00 hex] Acc_mode inactive
12:
[0C hex] Acc_mode not possible due to POWER ON fault
13:
[0D hex] Acc_mode not possible due to incorrect ID in p9570
15:
[0F hex] Acc_mode not possible due to expired Acc_timer
172:
[AC hex] Acc_mode active
Dependency:
Refer to: p9558, p9570
Refer to: C01799
Description:
Sets the delay time after which the pulses are safely canceled after a bus failure.
Dependency:
Refer to: p9561, p9563
Notice:
The parameter is being prepared and is presently ineffective.
Note:
A change only becomes effective after a POWER ON.
Description:
Displays the Safety Integrated version for the safety motion monitoring functions on the Control Unit.
p9570
SI motion acceptance test mode (Control Unit) / SI Mtn Acc_mode
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
00AC hex
0000 hex
r9571
SI motion acceptance test status (Control Unit) / SI Mtn acc_status
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
00AC hex
-
p9580
SI motion pulse cancelation delay time after bus failure (CU) / SI Mtn t to IL
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
800.00 [ms]
0.00 [ms]
r9590[0...2]
SI motion version safety motion monitoring (Control Unit) / SI Mtn version
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...