![Siemens SINAMICS S Series Скачать руководство пользователя страница 582](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427582.webp)
Parameters
List of parameters
1-582
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays additional information about the active alarm for float values.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays the second status word of faults and alarms.
Description:
Displays the second status word of faults and alarms.
r2134[0...63]
Alarm value for float values / Alarm value float
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8065
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r2135.0...15
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
A_INF, B_INF,
CU_CX32, CU_LINK,
CU_S, DMC20,
SERVO, S_INF,
TB30, TM15,
TM15DI_DO, TM17,
TM31, TM41,
TM54F_MA,
TM54F_SL
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2548
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Fault encoder 1
Yes
No
-
01
Fault encoder 2
Yes
No
-
02
Fault encoder 3
Yes
No
-
10
Fault transformer overtemperature
Yes
No
-
11
Alarm transformer overtemperature
Yes
No
-
12
Fault motor overtemperature
Yes
No
-
13
Fault thermal overload power unit
Yes
No
-
14
Alarm motor overtemperature
Yes
No
-
15
Alarm power unit thermal overload
Yes
No
-
r2135.0...15
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2548
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Fault encoder 1
Yes
No
-
01
Fault encoder 2
Yes
No
-
02
Fault encoder 3
Yes
No
-
12
Fault motor overtemperature
Yes
No
-
13
Fault thermal overload power unit
Yes
No
-
14
Alarm motor overtemperature
Yes
No
-
15
Alarm power unit thermal overload
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...