![Siemens SINAMICS S Series Скачать руководство пользователя страница 410](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427410.webp)
Parameters
List of parameters
1-410
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the scaling of the P gain of the velocity controller. This also makes the effective P gain
(including adaptations) scalable.
Description:
Displays the effective P gain of the speed controller.
Description:
Displays the effective P gain of the velocity controller.
Description:
Displays the effective P gain of the speed controller.
Dependency:
For p0528 = 1, the speed controller gain is represented without any dimensions. In this case, connector output sig-
nal r1468 is increased by a factor of 100 in order to improve the resolution.
Description:
Displays the effective integral time of the speed controller.
p1466[0...n]
CI: Velocity controller P gain scaling / v_ctrl Kp scal
SERVO (Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
5050
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1
r1468
Speed controller P-gain effective / n_ctrl Kp eff
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5040, 5042,
5210
P-Group:
Closed-loop control
Units group:
17_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [Nms/rad]
- [Nms/rad]
- [Nms/rad]
r1468
Velocity controller, P gain effective / v_ctrl Kp eff
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5040, 5042,
5210
P-Group:
Closed-loop control
Units group:
24_2
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [Ns/m]
- [Ns/m]
- [Ns/m]
r1468
CO: Speed controller P-gain effective / n_ctrl Kp eff
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
-
r1469
Speed controller integral time effective / n_ctrl Tn eff
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
5040, 5042,
6040
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...