Parameters
List of parameters
1-190
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Caution:
After booting or after a data set changeover, under certain circumstances, the new value is only available at BICO
sinks - that are interconnected to BICO source CO:r0479 - only after several 100ms as the connections must be
updated in the background (contrary to other BICO sources, e.g. CO:r0482).
The value is immediately available when non-cyclically reading r0479 (e.g. via the expert list).
Description:
Displays the encoder actual position value Gn_XIST1 according to PROFIdrive for diagnostics. In contrast to
p0482, the value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Description:
Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note:
When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished:
CI: p0480[0] = r2520[0], CI: p0480[1] = r2520[1] and CI: p0480[2] = r2520[2]
Description:
Displays the encoder status word Gn_ZSW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
r0479
CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer32
Dynamic index:
-
Func. diagram:
9674
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p0480[0...2]
CI: Signal source for encoder control word Gn_STW / Enc S_src Gn_STW
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Integer16
Dynamic index:
-
Func. diagram:
1580, 4720
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
r0481[0...2]
CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
4010, 4704,
4730
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Function 1 active
Yes
No
-
01
Function 2 active
Yes
No
-
02
Function 3 active
Yes
No
-
03
Function 4 active
Yes
No
-
04
Value 1
Displayed in r0483
Does not exist
-
05
Value 2
Displayed in r0483
Does not exist
-
06
Value 3
Displayed in r0483
Does not exist
-
07
Value 4
Displayed in r0483
Does not exist
-
08
Measuring probe 1 deflected
Yes
No
-
09
Measuring probe 2 deflected
Yes
No
-
11
Encoder fault acknowledge active
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...