![Siemens SINAMICS S Series Скачать руководство пользователя страница 789](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427789.webp)
List of parameters
Parameters
1-789
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Inversion using p4048 has been taken into account.
DO: Digital Output
Description:
Displays the status of the digital outputs of terminal module 31 (TM31).
Note:
Inversion using p4048 has been taken into account.
The setting of the DI/DO as either input or output is of no significance (p4028).
DO: Digital Output
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the status of the digital outputs of terminal module 41 (TM41).
Note:
Inversion using p4048 has been taken into account.
The setting of the DI/DO as either input or output is of no significance (p4028).
DO: Digital Output
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the status of the digital outputs of terminal module 15 (TM15).
r4047
TM31 digital outputs status / TM31 DO status
TM31
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
9556, 9560,
9562
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DO 0 (X542.1 - 3)
High
Low
-
01
DO 1 (X542.4 - 6)
High
Low
-
08
DI/DO 8 (X541.2)
High
Low
-
09
DI/DO 9 (X541.3)
High
Low
-
10
DI/DO 10 (X541.4)
High
Low
-
11
DI/DO 11 (X541.5)
High
Low
-
r4047
TM41 digital outputs status / TM41 DO status
TM41
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
08
DI/DO 0 (X521.1)
High
Low
9661
09
DI/DO 1 (X521.2)
High
Low
9661
10
DI/DO 2 (X521.3)
High
Low
9662
11
DI/DO 3 (X521.4)
High
Low
9662
r4047
TM15DI/DO digital outputs, status / TM15D DO status
TM15DI_DO
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
9400, 9401,
9402
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...