Parameters
List of parameters
1-492
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index:
[0] = Harmonics, phase U
[1] = Harmonics, phase V
[2] = Harmonics, phase W
[3] = Measured value phase U
[4] = Measured value phase V
[5] = Measured value phase W
Description:
Displays the phase correction voltages and and the drive converter phase voltages
Index:
[0] = Harmonics, phase U
[1] = Harmonics, phase V
[2] = Harmonics, phase W
[3] = Measured value phase U
[4] = Meaured value phase V
[5] = Measured value phase W
Description:
Sets the motor data identification and speed controller optimization.
p1900 = 0:
Function inhibited.
p1900 = 1:
Induction motors --> set p1910 = 1 and p1960 = 0, 1, 2 depending on p1300
Permanent-magnet or separately-excited synchronous motors --> set p1910 = 1, p1990 = 1 and p1960 = 0, 1, 2
depending on p1300
When the drive enable signals are present, a motor data identification routine is carried out at standstill with the
next power-on command. Current flows through the motor which means that it can align itself by up to a quarter of
a revolution.
For permanent-magnet or separately-excited synchronous motors, the encoder is adjusted with the next power-on
command. The motor must be free to rotate and rotates through 1.5 revolutions of the motor encoder.
With the following power-on command, a rotating motor data identification routine is carried out - and in addition, a
speed controller optimization by making measurements at different motor speeds.
p1900 = 2:
Induction motors --> set p1910 = 1 and p1960 = 0
Permanent-magnet or separately-excited synchronous motors --> set p1910 = 1, p1990 = 1 and p1960 = 0
When the drive enable signals are present, a motor data identification routine is carried out at standstill with the
next power-on command. Current flows through the motor which means that it can align itself by up to a quarter of
a revolution.
For permanent-magnet or separately-excited synchronous motors, the encoder is adjusted with the next power-on
command. The motor must be free to rotate and rotates through 1.5 revolutions of the motor encoder.
Values:
0:
Inhibited
1:
Motor data identification for rotating motor
2:
Motor data identification at standstill
r1849[0...5]
Actual value correction phase voltages / ActVal_corr V_corr
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Modulation
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p1900
Motor data identification and rotating measurement / Mot ID rot meas
VECTOR
Can be changed:
C2(1), T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 2
2
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...