![Siemens SINAMICS S Series Скачать руководство пользователя страница 1629](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271629.webp)
List of faults and alarms
Faults and Alarms
3-1629
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
C30701
SI Motion MM: STOP B initiated
Drive object:
SERVO, VECTOR
Reaction:
OFF3
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The drive is stopped via a STOP B (braking along the OFF3 ramp).
As a result of this fault, after the time, parameterized in p9356 has expired, or the speed threshold, parameterized
in p9360 has been fallen below, message C30700 "SI Motion MM: STOP A initiated" is output.
Possible causes:
- stop request from the Control Unit.
- subsequent response to the message C30714 "SI Motion MM: Safely limited speed exceeded".
- subsequent response to the message C30711 "SI Motion MM: Defect in a monitoring channel".
Remedy:
- remove the fault cause in the control and carry out a POWER ON.
- carry out a diagnostics routine for message C01714.
- carry out a diagnostics routine for message C01711.
This message can only be acknowledged in the acceptance test mode without POWER ON via the Terminal Module
54F (TM54F) or PROFIsafe.
Note:
SI: Safety Integrated
C30706
SI Motion MM: Safe Acceleration Monitor limit exceeded
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
After initiating STOP B or STOP C, the velocity has exceeded the selected tolerance.
The drive is shut down by the message C30700 "SI Motion MM: STOP A initiated".
Remedy:
Check the braking behavior, if required, adapt the tolerance for "Safe Acceleration Monitor".
This message can only be acknowledged in the acceptance test mode without POWER ON via the Terminal Module
54F (TM54F) or PROFIsafe.
Note:
SBR: Safe Acceleration Monitor
SI: Safety Integrated
See also: p9548 (SI motion SBR actual velocity tolerance (Control Unit))
C30707
SI Motion MM: Tolerance for safe operating stop exceeded
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The actual position has distanced itself further from the target position than the standstill tolerance.
The drive is shut down by the message C30701 "SI Motion MM: STOP B initiated".
Remedy:
- check whether safety faults are present and if required carry out the appropriate diagnostic routines for the partic-
ular faults.
- check whether the standstill tolerance matches the accuracy and control dynamic performance of the axis.
- carry out a POWER ON.
This message can only be acknowledged in the acceptance test mode without POWER ON via the Terminal Module
54F (TM54F) or PROFIsafe.
Note:
SI: Safety Integrated
SOS: Safe Operating Stop / SBH: Safe operating stop
See also: p9530 (SI motion standstill tolerance (Control Unit))
C30708
SI Motion MM: STOP C initiated
Drive object:
SERVO, VECTOR
Reaction:
STOP2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The drive is stopped via a STOP C (braking along the OFF3 ramp).
"Safe Operating Stop" (SOS) is activated after the parameterized timer stage has expired.
Possible causes:
- stop request from the higher-level control.
- subsequent response to the message C30714 "SI Motion MM: Safely limited speed exceeded".
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...