List of parameters
Parameters
1-283
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
r0975[6] = 9 --> PROFIdrive drive object sub-type class 1
r0975[7] = 2 --> drive object number = 2
r0975[8] = 0 (reserved)
r0975[9] = 0 (reserved)
r0975[10] = 600 --> second part, firmware version (complete version: V01.02.06.00)
Description:
Resets or downloads all parameters of the drive system.
Values:
0:
Inactive
1:
Starts to reset all parameters to factory setting
2:
Starts to download param. saved in non-volatile way w/ p0977 = 1
3:
Start to download the volatile parameters from RAM
10:
Starts to download param. saved in non-volatile way w/ p0977=10
11:
Starts to download param. saved in non-volatile way w/ p0977=11
12:
Starts to download param. saved in non-volatile way w/ p0977=12
20:
Starts to download Siemens internal setting 20
21:
Starts to download Siemens internal setting 21
22:
Starts to download Siemens internal setting 22
23:
Starts to download Siemens internal setting 23
24:
Starts to download Siemens internal setting 24
25:
Starts to download Siemens internal setting 25
26:
Starts to download Siemens internal setting 26
100:
Starts to reset all BICO interconnections
1011: Starts to download param. saved in volatile way w/ p0977 = 1011
1012: Starts to download param. saved in volatile way w/ p0977 = 1012
1013: Starts to download param. saved in volatile way w/ p0977 = 1013
Note:
After all of the parameters have been reset to their factory setting, the system must commissioned for the first time
again.
Resetting or loading is realized in the non-volatile memory.
Procedure:
1. Set p0009 = 30 (parameter reset).
2. Set p0976 to "required value". The system is rebooted.
p0976 is automatically set to 0 and p0009 is automatically set to 1 after this has been carried out.
Description:
Saves all parameters of the drive system to the non-volatile memory (CompactFlash card).
Values:
0:
Inactive
1:
Save in non-volatile fashion - downloaded at POWER ON
10:
Save as opt. in non-vol. fashion - downloaded w/ p0976=10
11:
Save as opt. in non-vol. fashion - downloaded w/ p0976=11
12:
Save as opt. in non-vol. fashion - downloaded w/ p0976=12
20:
Save in a non-volatile fashion as setting 20 (reserved)
21:
Save in a non-volatile fashion as setting 21 (reserved)
22:
Save in a non-volatile fashion as setting 22 (reserved)
p0976
Reset and load all parameters / Reset load all par
CU_CX32, CU_S
Can be changed:
C1(30)
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Factory settings
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1013
0
p0977
Save all parameters / Save all par
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Factory settings
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1013
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...