Description:
Displays the number of the cross-checked data which has caused STOP F on the Control Unit.
Dependency:
Refer to: r9895
Refer to: F01611
Note:
The complete list of numbers for data cross-check is listed in Fault F01611.
Description:
Displays the checksum over the checked Safety Integrated parameters on the Control Unit (actual checksum).
Dependency:
Refer to: p9799, r9898
Description:
Sets the checksum for the checked Safety Integrated parameters on the Control Unit (reference checksum).
Dependency:
Refer to: r9798, p9899
Description:
Sets the enable signals for safety functions on the Motor Module that are integrated in the drive.
Dependency:
Refer to: p9601
Note:
For p9801.2 = 1 and p9801.3 = 0 the following applies:
It is assumed that the motion monitoring functions integrated in the drive are controlled via the Terminal Module 54F
(TM54F).
MM: Motor Module
r9795
SI diagnostics STOP F (Control Unit) / SI diag STOP F CU
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9798
SI actual checksum SI parameters (Control Unit) / SI act_checksum CU
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2800
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p9799
SI reference checksum SI parameters (Control Unit) / SI set_checksum CU
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2800
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p9801
SI enable, functions integrated in the drive (Motor Module) / SI enable fct MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable STO (SH) via terminals (Motor Mod-
ule)
Enable
Inhibit
2810
02
Motion monitoring functions integr. in the
drive (Motor Module)
Enable
Inhibit
-
03
Enable PROFIsafe (Motor Module)
Enable
Inhibit
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...