Parameters
List of parameters
1-822
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the sampling time for the inputs and outputs of terminal module 41 (TM41).
Index:
[0] = Digital inputs/outputs (DI/DO)
[1] = Analog inputs (AI)
[2] = Does not exist
[3] = Encoder emulation
Dependency:
The parameter can only be modified for p0009 = 3, 29.
Refer to: p0009, r0110, r0111
Refer to: F35228
Note:
- the modified sampling time is not effective until the drive unit is powered-up again.
- the value of the sampling time of the Encoder Emulation p4099[3] can be preset. The next time that the system
boots, the validity of the value is checked. For an invalid value, fault F35228 is output and p4099[3] is automatically
set to the correct value. After this, the changed parameter must be saved.
- parameter p4099[0] must never equal zero.
Description:
The sampling time of the Terminal Module 17 (TM17) is determined by the DRIVE-CLiQ clock cyclic of the line to
which the module is attached. An entry is not possible using p4099. At power on, p4099 is correctly set to the result-
ing sampling time.
Description:
The sampling time of the Terminal Module 15 (TM15) is determined by the DRIVE-CLiQ clock cyclic of the line to
which the module is attached. An entry is not possible using p4099. At power on, p4099 is correctly set to the result-
ing sampling time.
p4099[0...3]
TM41 inputs/outputs, sampling time / TM41 I/O t_sample
TM41
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9660, 9661,
9662, 9663, 9674, 9676
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [µs]
5000.00 [µs]
[0] 4000.00 [µs]
[1] 4000.00 [µs]
[2] 0.00 [µs]
[3] 125.00 [µs]
p4099
TM17 inputs/outputs, sampling time / TM17 I/O t_sample
TM17
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
31.25 [µs]
500.00 [µs]
125.00 [µs]
p4099
TM15 inputs/outputs, sampling time / TM15 I/O t_sample
TM15
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
31.25 [µs]
500.00 [µs]
125.00 [µs]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...