List of parameters
Parameters
1-163
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the motor stator resistance at an ambient temperature p0625. The value does not include the cable resis-
tance.
Dependency:
Refer to: p0625
Description:
Displays the cable resistance between the Motor Module and motor.
Dependency:
Refer to: p0352
Description:
Displays the rated motor stator resistance at rated temperature (sum from p0625 and p0627).
Dependency:
Refer to: p0627
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the rotor/secondary section resistance of the motor for the ambient temperature p0625.
For separately-excited synchronous motors: Displays the damping resistance in the rotor direction (d-axis).
Dependency:
Refer to: p0625
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0370[0...n]
Motor stator resistance, cold / Mot R_stator cold
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
16_1
Unit selection:
p0349
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
r0372[0...n]
Cable resistance / Mot R_cable
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
16_1
Unit selection:
p0349
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
r0373[0...n]
Motor rated stator resistance / Mot R_stator rated
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
16_1
Unit selection:
p0349
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
r0374[0...n]
Motor rotor resistance cold / damping resistance d axis / Mot R_r cold / RDd
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
16_1
Unit selection:
p0349
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...