List of parameters
Parameters
1-363
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the bypass switch monitoring time.
Index:
[0] = Switch motor - drive
[1] = Switch motor - line supply
Note:
The monitoring is de-activated with p1274 = 0 ms.
Description:
Sets the control word for the motor holding brake.
Description:
Sets the delay time for closing the brake at standstill.
After this time has expired, if the "close brake at standstill" or OFF1/OFF3 is present, the brake is closed and the
pulses are canceled.
For p1276 = 300.000 s, the timer is de-activated - this means that the timer output is always zero.
Description:
Sets the delay time for the signal "braking threshold exceeded" (BO: r1229.6).
Dependency:
Refer to: p1220, p1221, r1229
p1274[0...1]
Bypass switch monitoring time / Switch t_monit
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
5000 [ms]
1000 [ms]
p1275
Motor holding brake control word / Brake STW
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Inverting BI: 1219[0]
Yes
No
2707
01
Inverting BI: 1219[1]
Yes
No
2707
02
Inverting BI: 1224[0]
Yes
No
2704
03
Inverting BI: 1224[1]
Yes
No
2704
05
Brake with feedback
Yes
No
2711
p1276
Motor holding brake, standstill detection, bypass / Brk standst bypass
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2704
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
300.000 [s]
300.000 [s]
p1277
Motor holding brake, braking threshold delay exceeded / Del thresh exceed.
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2707
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
300.000 [s]
0.000 [s]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...