List of parameters
Parameters
1-749
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the v coordinate of the 4th value pair of the friction characteristic.
Dependency:
Refer to: p3833, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 5th value pair of the friction characteristic.
Dependency:
Refer to: p3834, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the v coordinate of the 5th value pair of the friction characteristic.
Dependency:
Refer to: p3834, p3845
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 6th value pair of the friction characteristic.
Dependency:
Refer to: p3835, p3845
p3823[0...n]
Friction characteristic, value v3 / Friction v3
SERVO (Lin)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [m/min]
21000.00 [m/min]
12.00 [m/min]
p3824[0...n]
Friction characteristic, value n4 / Friction n4
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
210000.00 [RPM]
150.00 [RPM]
p3824[0...n]
Friction characteristic, value v4 / Friction v4
SERVO (Lin)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [m/min]
21000.00 [m/min]
15.00 [m/min]
p3825[0...n]
Friction characteristic, value n5 / Friction n5
SERVO, VECTOR
(n/M)
Can be changed:
T
Calculated:
CALC_MOD_LIM_REF
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7010
P-Group:
Functions
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
210000.00 [RPM]
300.00 [RPM]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...