List of parameters
Parameters
1-81
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the transformation angle.
Dependency:
Refer to: r0093, p0431, r1778
Note:
The transformation angle corresponds to the electrical commutation angle.
If no pole position identification is carried out (p1982), and the encoder is adjusted, the following applies:
The encoder supplies the value and indicates the electrical angle of the flux position (d axis).
Description:
Executes an automatic device configuration.
In so doing, p0099, p0107 and p0108 are appropriately set.
Values:
0:
No selection
1:
Drive object type SERVO
2:
Drive object type VECTOR
3:
SINAMICS GM (DFEMV & VECTORMV)
4:
SINAMICS SM (AFEMV & VECTORMV)
5:
SINAMICS GL (VECTORGL)
12:
Drive object type VECTOR parallel circuit
13:
Drive object type VECTORMV - GM parallel circuit
14:
Drive object type VECTORMV - SM parallel circuit
Dependency:
Refer to: r0098, p0099
Refer to: A01330
Note:
For p0097 = 0, p0099 is automatically set to the factor setting.
The setting p0097 = 1 is not possible for chassis-type power units as well as for SINAMICS G or SINAMICS GM.
The setting p0097 = 12 is not possible for booksize power units.
Description:
Displays the automatically detected actual device topology in coded form.
Index:
[0] = DRIVE-CLiQ socket X100
[1] = DRIVE-CLiQ socket X101
[2] = DRIVE-CLiQ socket X102
[3] = DRIVE-CLiQ socket X103
[4] = DRIVE-CLiQ socket X104
[5] = DRIVE-CLiQ socket X105
Dependency:
Refer to: p0097, p0099
r0094
CO: Transformation angle / Transformat_angle
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1580, 4710,
4715, 6714, 6730
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [°]
- [°]
- [°]
p0097
Select drive object type / Select DO type
CU_CX32, CU_S
Can be changed:
C1(1)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 14
0
r0098[0...5]
Actual device topology / Device_act topo
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Topology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...