![Siemens SINAMICS S Series Скачать руководство пользователя страница 763](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427763.webp)
List of parameters
Parameters
1-763
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
BI: p3873 = 1 signal --> closed-loop control with encoder
BI: p3873 = 0 signal --> sensorless closed-loop control
For a 0/1 edge, the commutation angle is set from CI: p3874.
Description:
Sets the signal source for the commutation angle for operation with encoder.
Dependency:
Refer to: p3870, p3871, p3872, p3873, r3875, p3876, p3878, p3879
Note:
This angle is set for a 0/1 signal edge via BI: p3873.
Description:
Displays the status word for long stator motors.
Dependency:
Refer to: p3870, p3871, p3872, p3873, p3874, p3876, p3878, p3879
Note:
The display is updated with a sampling time of 1 ms.
Re bit 00 = 1:
The encoder is parked. Contrary to r0481.14, parking is also displayed here if the suppression of the parking bit is
active in r0481.14 (p3870.1 = 1).
Re bit 01 = 1:
The long-stator functions requested closed-loop speed control with encoder. In r1407.2, it is indicated as to whether
an encoder is actually used for the closed-loop control.
Description:
Displays the status word for long stator motors.
Dependency:
Refer to: p3870, p3871, p3872, p3873, p3874, p3876, p3878, p3879
Note:
The display is updated with a sampling time of 1 ms.
p3874
CI: Long stator signal source commutation angle oper. with encoder /
S_src com_ang enc
SERVO
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
3879[0]
r3875.0...1
CO/BO: Long stator status word / Long stator ZSW
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Sensor Module is unparked
Yes
No
-
01
Closed-loop speed control with encoder
requested
Active
Inactive
-
r3875.0...1
CO/BO: Long stator status word / Long stator ZSW
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Sensor Module is unparked
Yes
No
-
01
Closed-loop velocity control with encoder
requested
Active
Inactive
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...