Parameters
List of parameters
1-608
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the value for fixed value 11 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets the value for fixed value 13 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets the value for fixed value 14 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
p2211[0...n]
CO: Technology controller, fixed value 11 / Tec_ctrl fix val11
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
110.00 [%]
p2212[0...n]
CO: Technology controller, fixed value 12 / Tec_ctrl fix val12
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
120.00 [%]
p2213[0...n]
CO: Technology controller, fixed value 13 / Tec_ctrl fix val13
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
130.00 [%]
p2214[0...n]
CO: Technology controller, fixed value 14 / Tec_ctrl fix val14
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
140.00 [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...