Parameters
List of parameters
1-220
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Factor to evaluate the stator resistance.
Dependency:
Refer to: p0350, r0370
Description:
Factor to evaluate the stator leakage inductance.
Dependency:
Refer to: p0356, r0377
Description:
Factor to evaluate the magnetizing inductance in the direction of the rotor axis (d axis).
Dependency:
Refer to: p0360, r0382
Description:
Factor to evaluate the magnetizing inductance quadrature to the rotor axis (q axis).
Dependency:
Refer to: p0361, r0383
Description:
Factor to evaluate the damping inductance in the direction of the rotor axis (d axis).
Dependency:
Refer to: p0358, r0380
p0652[0...n]
Motor stator resistance, scaling / Mot R_stator scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0653[0...n]
Motor stator leakage inductance, scaling / Mot L_S_leak scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0655[0...n]
Motor magnetizing inductance, d axis saturated scaling / Mot L_m d sat scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0656[0...n]
Motor magnetizing inductance, q axis, saturated scaling / Mot L_m q sat scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
p0657[0...n]
Motor damping inductance, d axis scaling / Mot L_damp d scal
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_EQU
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
10.0 [%]
300.0 [%]
100.0 [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...