Description:
Sets the offset voltage in the alpha direction; this compensates the offset voltages of the drive converter/inverter at
low speeds. The value is valid for the rated (nominal) pulse frequency of the Motor Module.
Note:
The value is pre-set during the rotating measurement.
Description:
Sets the offset voltage in the beta direction; this compensates the offset voltages of the drive converter/inverter at
low speeds. The value is valid for the rated (nominal) pulse frequency of the Motor Module.
Note:
The value is pre-set during the rotating measurement.
Description:
Induction motor (ASM):
Displays the difference between the motor model flux angle and the transformation angle.
Permanent magnet synchronous motor (PEM):
Displays the difference between the motor model angle and the encoder angle.
Description:
Displays the absolute value of the flux of the motor model.
p1774[0...n]
Motor model, offset voltage compensation alpha / MotMod offs comp A
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
-5.000 [V]
5.000 [V]
0.000 [V]
p1775[0...n]
Motor model, offset voltage compensation beta / MotMod offs comp B
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
-5.000 [V]
5.000 [V]
0.000 [V]
r1778
Motor model flux angle difference / MotMod ang. diff.
SERVO, VECTOR
(n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [°]
- [°]
- [°]
r1779
Motor model absolute flux / MotMod abs flux
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...