List of parameters
Parameters
1-507
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the identified magnetizing current.
Dependency:
Refer to: r1936, p1959, p1960
Note:
This value corresponds to the magnetizing current (p0320 / r0331).
Description:
The identified characteristic of the voltage emulation error is displayed r1950[0...19] and r1951[0...19].
Dependency:
Refer to: r1951
Description:
The identified characteristic of the voltage emulation error is displayed r1950[0...19] and r1951[0...19].
Dependency:
Refer to: r1950
Description:
Sets the final value to compensate the voltage emulation error.
Dependency:
Refer to: p1953
Note:
The voltage emulation error is calculated and compensated for every phase according to the following formula:
u_error = u0 * i / (abs(i)-i0)
u0: This is set in p1952.
i0: This is set in p1953.
i: Phase current to which the emulation error u_error belongs.
r1948
Magnetizing current identified / I_mag ident
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r1950[0...19]
Voltage emulation error voltage values / V_error V_values
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r1951[0...19]
Voltage emulation error current values / V_error I_error
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
p1952[0...n]
Voltage emulation error final value / V_error final val
SERVO (Exp M_ctrl)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [V]
100.000 [V]
0.000 [V]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...