Parameters
List of parameters
1-824
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index:
[0] = Alarm threshold
[1] = Fault threshold
Dependency:
Refer to: r4104
Warning:
Fault F35207 only causes the drive to be shut down if there is at least one BICO interconnection between the drive
and TM31.
Note:
The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
A value > 250 °C deactivates the alarm or fault.
Description:
Displays the status for the temperature evaluation of terminal module 31 (TM31).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
Dependency:
Refer to: p4102
Description:
Displays the actual temperature value of the temperature evaluation of terminal module 31 (TM31).
Dependency:
For sensor type PTC (p4100 = 1), the following applies:
- below the nominal response temperature, r4105 = -50°C.
- above the nominal response temperature, r4105 = 250 °C.
For sensor type KTY84-130 (p4100 = 2), the following applies:
- the displayed value corresponds to the temperature actual value.
Refer to: p4100
Note:
The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
For an invalid temperature actual value, (e.g. a short-circuit at the sensor input), r4105 = -300 °C is displayed.
Description:
Displays the unfiltered speed setpoint N_SETPT in revolutions per minute for diagnostic purposes.
In contrast to p1155, this value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Dependency:
Refer to: r4155
r4104.0...1
BO: TM31 temperature evaluation, status / TM31 temp status
TM31
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1840, 9576
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Temperature alarm threshold exceeded
Yes
No
-
01
Temperature fault threshold exceeded
Yes
No
-
r4105
CO: TM31 temperature evaluation, actual value / TM31 temp actValue
TM31
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1840, 9576
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r4154
TM41 diagnostics speed setpoint non-filtered / n_set non-filt
TM41
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...