List of parameters
Parameters
1-605
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Re bit 00:
The velocity threshold value 3 is set in p2161.
Re bit 01:
The comparison value is set in p2141.
Re bit 11:
The force threshold value 2 is set in p2194.
Description:
Sets the signal source to switch-in/switch-out the technology controller.
The technology controller is switched-in with a 1 signal.
Description:
Sets the value for fixed value 1 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description:
Sets the value for fixed value 2 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
|v_act| < velocity threshold value 3
Yes
No
8010
01
f or v comparison value reached or
exceeded
Yes
No
8010
04
Velocity setpoint - actual value deviation in
tolerance t_on
Yes
No
8010
05
Ramp-up/ramp-down completed
Yes
No
8010
06
Current below the zero current threshold
Yes
No
-
11
Force utilization < force threshold value 2
Yes
No
8012
p2200[0...n]
BI: Technology controller enable / Tec_ctrl enable
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2201[0...n]
CO: Technology controller, fixed value 1 / Tec_ctrl fix val 1
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
10.00 [%]
p2202[0...n]
CO: Technology controller, fixed value 2 / Tec_ctrl fix val 2
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
7950
P-Group:
Technology
Units group:
9_1
Unit selection:
p0595
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
20.00 [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...